Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual
Page 18
4
OPERATION
18
UFC 400
www.krohne.com
05/2013 - 4002813701 - AD FF UFC 400 R01 en
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_23
ACTIVE_23
ACTIVE_23
ACTIVE_23
FD_EXTENDED_
ACTIVE_23
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_24
ACTIVE_24
ACTIVE_24
ACTIVE_24
FD_EXTENDED_
ACTIVE_24
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_25
ACTIVE_25
ACTIVE_25
ACTIVE_25
FD_EXTENDED_
ACTIVE_25
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(06) IO B Simulation Active / (07) IO B Sim. Binary Output / (08)
IO B Sim. Current In-/Output / (09) IO B Sim. Limit Sw./Current
Out / (10) IO A Sim. Binary Output / (11) IO A Sim. Current In-
/Output / (12) IO A Sim. Limit Sw./Current Out / (30) VoS
Simulation Active / (31) Flow Simulation Active
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_26
ACTIVE_26
ACTIVE_26
ACTIVE_26
FD_EXTENDED_
ACTIVE_26
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_27
ACTIVE_27
ACTIVE_27
ACTIVE_27
FD_EXTENDED_
ACTIVE_27
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_28
ACTIVE_28
ACTIVE_28
ACTIVE_28
FD_EXTENDED_
ACTIVE_28
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_29
ACTIVE_29
ACTIVE_29
ACTIVE_29
FD_EXTENDED_
ACTIVE_29
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(02) IO B Binary Output Config / (03) IO B Current In-/Output
Config / (04) IO A Binary Output Config / (05) IO A Current In-
/Output Config. / (10) IO2 Configuration / (11) IO1
Configuration / (12) Display Config. / (26) Process Input
Config. / (30) DM Configuration / (31) BM Configuration
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_30
ACTIVE_30
ACTIVE_30
ACTIVE_30
FD_EXTENDED_
ACTIVE_30
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(01) IO B Failure / (02) IO A Failure / (07) IO 2 Failure / (08) IO 1
Failure / (18) Sensor Driver Failure / (19) DSP Failure / (20)
uProc. Failure / (21) FrontEnd Failure / (26) DM Failure / (27)
BM Failure / (28) HW Combination Error / (31) System Error
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
ACTIVE_31
ACTIVE_31
ACTIVE_31
ACTIVE_31
FD_EXTENDED_
ACTIVE_31
R
An optional parameter to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE
parameter.
Uninitialized
Setting:
(31) Crossed Cabling
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value