Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual

Page 14

background image

4

OPERATION

14

UFC 400

www.krohne.com

05/2013 - 4002813701 - AD FF UFC 400 R01 en

FD_CHECK_MAP

FD_CHECK_MAP

FD_CHECK_MAP

FD_CHECK_MAP

Check Map

R/W

This parameter enables or disables conditions to be detected

as active for this alarm category.

(24) (25) (26) (27)

Setting:

(00) Check / (01) Electronics : Operation Info /

(08) Electronics : Power Fail / (10) Configuration : Totaliser /

(11) Process : Signal Unreliable / (12) Process : Signal Lost /

(13) Process : Empty Pipe / (14) Electronics : IO Connection /

(15) Process : Current input / (16) M Process /

(17) M Configuration / (18) M Electronics / (19) M Sensor /

(20) S Process / (21) S Configuration / (22) S Electronics /

(23) S Sensor / (24) C Process / (25) C Configuration /

(26) C Electronics / (27) C Sensor / (28) F Process / (29) F

Configuration / (30) F Electronics / (31) F Sensor

FD_CHECK_MASK

FD_CHECK_MASK

FD_CHECK_MASK

FD_CHECK_MASK

Check Mask

R/W

This parameter allows the user to suppress any single or

multiple conditions that are active, in this category, from

being broadcast to the host through the alarm parameter.

Setting:

(00) Check / (01) Electronics : Operation Info /

(08) Electronics : Power Fail / (10) Configuration : Totaliser /

(11) Process : Signal Unreliable / (12) Process : Signal Lost /

(13) Process : Empty Pipe / (14) Electronics : IO Connection /

(15) Process : Current input / (16) M Process /

(17) M Configuration / (18) M Electronics / (19) M Sensor /

(20) S Process / (21) S Configuration / (22) S Electronics /

(23) S Sensor / (24) C Process / (25) C Configuration /

(26) C Electronics / (27) C Sensor / (28) F Process / (29) F

Configuration / (30) F Electronics / (31) F Sensor

FD_CHECK_PRI

FD_CHECK_PRI

FD_CHECK_PRI

FD_CHECK_PRI

Check Priority

R/W

This parameter allows the user to specify the priority of this

alarm category.

0

Setting:

0...15

FD_FAIL_ACTIVE

FD_FAIL_ACTIVE

FD_FAIL_ACTIVE

FD_FAIL_ACTIVE

Fail Active

R

This parameter reflects the error conditions that are being

detected as active as selected for this category. It is a bit

string, so that multiple conditions may be shown. See section

2.9.

Uninitialized

Setting:

(00) Check / (01) Electronics : Operation Info /

(08) Electronics : Power Fail / (10) Configuration : Totaliser /

(11) Process : Signal Unreliable / (12) Process : Signal Lost /

(13) Process : Empty Pipe / (14) Electronics : IO Connection /

(15) Process : Current input / (16) M Process /

(17) M Configuration / (18) M Electronics / (19) M Sensor /

(20) S Process / (21) S Configuration / (22) S Electronics /

(23) S Sensor / (24) C Process / (25) C Configuration /

(26) C Electronics / (27) C Sensor / (28) F Process / (29) F

Configuration / (30) F Electronics / (31) F Sensor

FD_FAIL_ALM

FD_FAIL_ALM

FD_FAIL_ALM

FD_FAIL_ALM

Fail Diagnostic Alarm

This parameter is used primarily to broadcast a change in the

associated active conditions, which are not masked, for this

alarm category to a Host System.

-

Unacknowledged

R/W

A discrete enumeration which is set to "Unacknowledged"

when an alarm occurs, and set to "Acknowledged" by a write

from a human interface device or other entity which can

acknowledge that the alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized / Acknowledged / Unacknowledged

Alarm State

R

A discrete enumeration which gives an indication of whether

the alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value