beautypg.com

Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual

Page 44

background image

4

OPERATION

44

UFC 400

www.krohne.com

05/2013 - 4002813701 - AD FF UFC 400 R01 en

LIMITATION_MIN

LIMITATION_MIN

LIMITATION_MIN

LIMITATION_MIN

Lower Limit

R/W

Lower limitation of all flow values , before smoothing by time

constant, affects all outputs (Fct. C1.3.1).

-20.0 m/s

Settings:

-0.0010…-1000.0 m/s

LINEARIZATION

LINEARIZATION

LINEARIZATION

LINEARIZATION

Linearization

R/W

(Compensation for errors made at different Reynolds

Numbers (Fct. C1.7.1).

off

Settings:

off / on

LOW_FLOW_

LOW_FLOW_

LOW_FLOW_

LOW_FLOW_

CUTOFF

CUTOFF

CUTOFF

CUTOFF

Low flow cutoff

R/W

Sets the low flow cutoff (Fct. C1.3.4).

0.0 m/s

Settings:

0.0...100.0 m/s

METER_SIZE_

METER_SIZE_

METER_SIZE_

METER_SIZE_

FREE_VAL

FREE_VAL

FREE_VAL

FREE_VAL

Meter size

R/W

Sets the pipe diameter (Fct. C1.1).

100.0 mm

Settings:

25.0…3000.0 mm

METER_SIZE_

METER_SIZE_

METER_SIZE_

METER_SIZE_

TBL_VAL

TBL_VAL

TBL_VAL

TBL_VAL

Meter size

R/W

Sets the pipe diameter (Fct. C1.1).

100 mm

Settings:

250:25 mm (1 inch) / 320:32 mm (1.25 inch) / 400:40 mm (1.5

inch) / 500:50 mm (2 inch) / 650:65 mm (2.5 inch) / 800:80 mm

(3 inch) / 1000:100 mm (4 inch) / 1250:125 mm (5 inch) /

1500:150 mm (6 inch) / 2000:200 mm (8 inch) / 2500:250 mm

(10 inch) / 3000:300 mm (12 inch) / 3500:350 mm (14 inch) /

4000:400 mm (16 inch) / 4500:450 mm (18 inch) / 5000:500

mm (20 inch) / 5500:550 mm (22 inch) / 6000:600 mm (24

inch) / 6500:650 mm (26 inch) / 7000:700 mm (28 inch) /

7500:750 mm (30 inch) / 8000:800 mm (32 inch) / 8500:850

mm (34 inch) / 9000:900 mm (36 inch) / 9500:950 mm (38

inch) / 10000:1000 mm (40 inch) / 10500:1050 mm (42 inch) /

11000:1100 mm (44 inch) / 11500:1150 mm (46 inch) /

12000:1200 mm (48 inch) / 12500:1250 mm (50 inch) /

13000:1300 mm (52 inch) / 13500:1350 mm (54 inch) /

14000:1400 mm (56 inch) / 14500:1450 mm (58 inch) /

15000:1500 mm (60 inch) / 16000:1600 mm (64 inch) /

17000:1700 mm (68 inch) / 18000:1800 mm (72 inch) /

19000:1900 mm (76 inch) / 20000:2000 mm (80 inch) /

21000:2100 mm (84 inch) / 22000:2200 mm (88 inch) /

23000:2300 mm (92 inch) / 24000:2400 mm (96 inch) /

25000:2500 mm (100 inch) / 26000:2600 mm (104 inch) /

27000:2700 mm (108 inch) / 28000:2800 mm (112 inch) /

29000:2900 mm (116 inch) / 30000:3000 mm (120 inch)

NUM_PATHS

NUM_PATHS

NUM_PATHS

NUM_PATHS

Number of paths

R/W

Sets the number of active paths (Fct. D2.1).

3 paths

Settings:

1 path / 2 paths / 3 paths

PATH_LENGTH_1

PATH_LENGTH_1

PATH_LENGTH_1

PATH_LENGTH_1

Path length 1

R/W

Shows/Sets the length of path 1 (Fct. D2.3).

100 mm

Settings:

12.5…6000.0 mm

PATH_LENGTH_2

PATH_LENGTH_2

PATH_LENGTH_2

PATH_LENGTH_2

Path length 2

R/W

Shows/Sets the length of path 2 (Fct. D2.4).

100 mm

Settings:

12.5…6000.0 mm

PATH_LENGTH_3

PATH_LENGTH_3

PATH_LENGTH_3

PATH_LENGTH_3

Path length 3

R/W

Shows/Sets the length of path 3 (Fct. D2.5).

100 mm

Settings:

12.5…6000.0 mm

PING_TIME

PING_TIME

PING_TIME

PING_TIME

Ping time

R/W

Ping time (Fct. D1.11)

15.5 ms

Settings:

5.0…15.0 ms

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value