Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual
Page 21
OPERATION
4
21
UFC 400
www.krohne.com
05/2013 - 4002813701 - AD FF UFC 400 R01 en
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
24
24
24
24
FD_EXTENDED_MAP_
24
R
Field Diagnostics of "C Process"
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
25
25
25
25
FD_EXTENDED_MAP_
25
R/W
Field Diagnostics of "C Configuration"
Uninitialized
Setting:
(06) IO B Simulation Active / (07) IO B Sim. Binary Output / (08)
IO B Sim. Current In-/Output / (09) IO B Sim. Limit Sw./Current
Out / (10) IO A Sim. Binary Output / (11) IO A Sim. Current In-
/Output / (12) IO A Sim. Limit Sw./Current Out / (30) VoS
Simulation Active / (31) Flow Simulation Active
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
26
26
26
26
FD_EXTENDED_MAP_
26
R
Field Diagnostics of "C Electronics"
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
27
27
27
27
FD_EXTENDED_MAP_
27
R
Field Diagnostics of "C Sensor"
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
28
28
28
28
FD_EXTENDED_MAP_
28
R
Field Diagnostics of "F Process"
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
29
29
29
29
FD_EXTENDED_MAP_
29
R/W
Field Diagnostics of "F Configuration"
Uninitialized
Setting:
(02) IO B Binary Output Config / (03) IO B Current In-/Output
Config / (04) IO A Binary Output Config / (05) IO A Current In-
/Output Config. / (10) IO2 Configuration / (11) IO1
Configuration / (12) Display Config. / (26) Process Input
Config. / (30) DM Configuration / (31) BM Configuration
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
30
30
30
30
FD_EXTENDED_MAP_
30
R/W
Field Diagnostics of "F Electronics"
Uninitialized
Setting:
(01) IO B Failure / (02) IO A Failure / (07) IO 2 Failure / (08) IO 1
Failure / (18) Sensor Driver Failure / (19) DSP Failure / (20)
uProc. Failure / (21) FrontEnd Failure / (26) DM Failure / (27)
BM Failure / (28) HW Combination Error / (31) System Error
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
31
31
31
31
FD_EXTENDED_MAP_
31
R/W
Field Diagnostics of "F Sensor"
Uninitialized
Setting:
(31) Crossed Cabling
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
Maintenance Active
R
This parameter reflects the error conditions that are being
detected as active as selected for this category. It is a bit
string, so that multiple conditions may be shown. See section
2.9.
Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(08) Electronics : Power Fail / (10) Configuration : Totaliser /
(11) Process : Signal Unreliable / (12) Process : Signal Lost /
(13) Process : Empty Pipe / (14) Electronics : IO Connection /
(15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process / (29) F
Configuration / (30) F Electronics / (31) F Sensor
FD_MAINT_ALM
FD_MAINT_ALM
FD_MAINT_ALM
FD_MAINT_ALM
Fail Maintenance
Alarm
This parameter is used primarily to broadcast a change in the
associated active conditions, which are not masked, for this
alarm category to a Host System.
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value