beautypg.com

Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual

Page 21

background image

OPERATION

4

21

UFC 400

www.krohne.com

05/2013 - 4002813701 - AD FF UFC 400 R01 en

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

24

24

24

24

FD_EXTENDED_MAP_

24

R

Field Diagnostics of "C Process"

Uninitialized

Setting:

(00) Reserved

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

25

25

25

25

FD_EXTENDED_MAP_

25

R/W

Field Diagnostics of "C Configuration"

Uninitialized

Setting:

(06) IO B Simulation Active / (07) IO B Sim. Binary Output / (08)

IO B Sim. Current In-/Output / (09) IO B Sim. Limit Sw./Current

Out / (10) IO A Sim. Binary Output / (11) IO A Sim. Current In-

/Output / (12) IO A Sim. Limit Sw./Current Out / (30) VoS

Simulation Active / (31) Flow Simulation Active

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

26

26

26

26

FD_EXTENDED_MAP_

26

R

Field Diagnostics of "C Electronics"

Uninitialized

Setting:

(00) Reserved

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

27

27

27

27

FD_EXTENDED_MAP_

27

R

Field Diagnostics of "C Sensor"

Uninitialized

Setting:

(00) Reserved

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

28

28

28

28

FD_EXTENDED_MAP_

28

R

Field Diagnostics of "F Process"

Uninitialized

Setting:

(00) Reserved

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

29

29

29

29

FD_EXTENDED_MAP_

29

R/W

Field Diagnostics of "F Configuration"

Uninitialized

Setting:

(02) IO B Binary Output Config / (03) IO B Current In-/Output

Config / (04) IO A Binary Output Config / (05) IO A Current In-

/Output Config. / (10) IO2 Configuration / (11) IO1

Configuration / (12) Display Config. / (26) Process Input

Config. / (30) DM Configuration / (31) BM Configuration

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

30

30

30

30

FD_EXTENDED_MAP_

30

R/W

Field Diagnostics of "F Electronics"

Uninitialized

Setting:

(01) IO B Failure / (02) IO A Failure / (07) IO 2 Failure / (08) IO 1

Failure / (18) Sensor Driver Failure / (19) DSP Failure / (20)

uProc. Failure / (21) FrontEnd Failure / (26) DM Failure / (27)

BM Failure / (28) HW Combination Error / (31) System Error

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

FD_EXTENDED_MAP_

31

31

31

31

FD_EXTENDED_MAP_

31

R/W

Field Diagnostics of "F Sensor"

Uninitialized

Setting:

(31) Crossed Cabling

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

FD_MAINT_ACTIVE

Maintenance Active

R

This parameter reflects the error conditions that are being

detected as active as selected for this category. It is a bit

string, so that multiple conditions may be shown. See section

2.9.

Uninitialized

Setting:

(00) Check / (01) Electronics : Operation Info /

(08) Electronics : Power Fail / (10) Configuration : Totaliser /

(11) Process : Signal Unreliable / (12) Process : Signal Lost /

(13) Process : Empty Pipe / (14) Electronics : IO Connection /

(15) Process : Current input / (16) M Process /

(17) M Configuration / (18) M Electronics / (19) M Sensor /

(20) S Process / (21) S Configuration / (22) S Electronics /

(23) S Sensor / (24) C Process / (25) C Configuration /

(26) C Electronics / (27) C Sensor / (28) F Process / (29) F

Configuration / (30) F Electronics / (31) F Sensor

FD_MAINT_ALM

FD_MAINT_ALM

FD_MAINT_ALM

FD_MAINT_ALM

Fail Maintenance

Alarm

This parameter is used primarily to broadcast a change in the

associated active conditions, which are not masked, for this

alarm category to a Host System.

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value