Operation – KROHNE UFC 400 FOUNDATION FIELDBUS EN User Manual
Page 19
OPERATION
4
19
UFC 400
www.krohne.com
05/2013 - 4002813701 - AD FF UFC 400 R01 en
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
1111
FD_EXTENDED_MAP_
1
R/W
Field Diagnostics of "Electronics : Operation Info"
Uninitialized
Setting:
(00) Optical Interf. Active / (01) Disp. 2 Overrange / (02) Disp. 1
Overrange / (06) RB is set to OOS / (07) Fieldbus No
Connection / (11) Status Out B Active / (13) Status Out A
Active / (14) Control In B Active / (15) Control In A Active / (30)
Sensor Starting up / (31) Zero Calibr. Running
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
2222
FD_EXTENDED_MAP_
2
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(20) Disp. 2 no measure values / (21) Dsp. 1 no measure
values / (28) IO B No Value for Binary Output / (29) IO B No
Value for Current Output / (30) IO A No Value for Binary
Output / (31) IO A No Value for Current Output
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
3333
FD_EXTENDED_MAP_
3
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
4444
FD_EXTENDED_MAP_
4
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
5555
FD_EXTENDED_MAP_
5
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
6666
FD_EXTENDED_MAP_
6
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
7777
FD_EXTENDED_MAP_
7
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
8888
FD_EXTENDED_MAP_
8
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
9999
FD_EXTENDED_MAP_
9
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
10
10
10
10
FD_EXTENDED_MAP_
10
R
An optional parameter to allow the user finer control on
enabling conditions contributing to the conditions in
FD_*_ACTIVE parameter.
Uninitialized
Setting:
(00) Reserved
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value