background image

LIST OF

WARNINGS AND CAUTIONS

BOP 1KW OPR 3/10/14

G/(H Blank)

PAGE

WARNING/CAUTION

tated.

3-19

CAUTION:

When working with active loads, always adjust the BOP protection limits

to be above the maximum values of voltage or current expected from the

load. For example, when the BOP is operating in voltage mode sinking

energy from a constant current type load, set the current protection limits

of the BOP above the maximum current expected from the load.

3-26

CAUTION:

Before Pressing

@

to enter the Saved Waveform Screen from the power-

up screen, perform the following steps to avoid unexpected voltages or

currents from previous settings being briefly applied to the load when the

waveform is first executed.

3-35

CAUTION:

Pressing RESET will cause voltage transients to appear at the output

which may damage a connected load. Switch is recessed to prevent inad-

vertent activation.

3-44

CAUTION:

The commands listed above with (**) will generate a “-420, Missing Que-

ry” error if a query does not precede the command in the same command

string or

;*OPC?

does not follow the command. Although commands not

marked with (**) will not generate an error, all commands listed above re-

quire verification to insure absolute success. Failure to follow these

rules can result in the loss of all stored constants and render the unit in-

operative.

3-53

CAUTION:

When the serial port has received an XOFF, the error message -400, QUE

error will be placed in the queue to indicate the loss of transmitted infor-

mation due to a received XOFF character. When XON is received, the unit

will transmit all data in it's buffer followed by the exclamation character

(!). This (!) character is not part of any message from the BOP and indi-

cates the transmission buffer has been cleared and the BOP is idle.

4-11

CAUTION:

If the CALIBRATE ZERO

!

function is available, perform this function