Earth ground connection recommendations -10, Wrong, Correct – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.12 and higher User Manual

Page 48

background image

2-10

BOP HIPWR 031014

FIGURE 2-2. EARTH GROUND CONNECTION RECOMMENDATIONS

EXT
REF

SGND

ANALOG

I/O PORT

COM

OUT

LOAD

IOUT

PROGRAMMING
DEVICE

BOP 1KW

LOAD

SGND

COM

EXT

REF

PROGRAMMING
DEVICE

BOP 1KW

OUT

OUT

I

CONNECTION

MISSING

ANALOG

I/O PORT

With two earth-ground points as
shown, a ground loop allows return
current to flow through the internal
circuits of the BOP as well as through
the proper return path.

With two earth-ground points as
shown, if the return connection from
the load to BOP COM is missing, all
the output current flows through the
internal circuits of the BOP causing
catastrophic damage to the BOP.

WRONG!

LOAD

SGND

COM

EXT

REF

PROGRAMMING
DEVICE

ANALOG

I/O PORT

BOP 1KW

OUT

OUT

I

EXT

REF

PROGRAMMING
DEVICE

ANALOG

I/O PORT

SGND

COM

BOP 1KW

OUT

OUT

I

LOAD

EXT

REF

PROGRAMMING
DEVICE

ANALOG

I/O PORT

OUT

OUT

SGND

COM

LOAD

BOP 1KW

I

3043801

CORRECT!