KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.12 and higher User Manual

Page 24

background image

1-4

BOP HIPWR 031014

OUTPUT CHARACTERISTICS (Continued)

Series-parallel Operation

2 series x 2 parallel
3 series x 2 parallel

Master/slave for both series and parallel
branches of identical units

Power-up timing
(parallel, series and series-parallel systems)

15 Sec max.

For system to be able to respond to analog or
digital control.

Output Protection
limiting

Analog Voltage and current limited in four quadrants, adjustable between 0.5% and 101%of

EO

NOM

or IO

NOM

. The analog limits are converted to digital limits at 2mS update rate.

Digital Voltage and current limited in four quadrants, adjustable between ±Internal minimum

EO

MIN

or IO

MIN

(box) (see Figure 1-3) and ±1.01 EO

NOM

or IO

NOM

.

Output Stage Protection

Output overvoltage/overcurrent

Heatsink overtemperature,

switchers overcurrent

Triggers latched shutdown protection of the
output module and PFC stage. Recover by
cycling power off, then on or by pressing
RESET at the front panel.

Input Stage Protection (PFC)

Internal overvoltage, undervoltage,

overcurrent, heat sink

overtemperature, fan inoperative

Input circuit breaker overcurrent

Trips circuit breaker to shut off unit

Small signal
Bandwidth

voltage channel

2 KHz minimum

Into nominal resistive load 10% of rating

current channel

800 Hz minimum

(BOP 6-125MG: 600 Hz minimum)

Into short circuit, 10% of rating

Rise/Fall time

voltage channel

250/200

µ

S

Into nominal resistive load, measured from 10
to 90%, from 0 to ±100% of rating

current channel

0.7/1.2 mS

Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating

PROGRAMMING/DISPLAY CHARACTERISTICS

Analog I/O Port
(See Table 2-10)

Main

channel

(voltage or current)

–10V to +10V

Full range output, 20K Ohm input impedance
(see PAR. 3.4)

Protection Limit

channels:

(±Voltage, ±Current)

+0.05V to +10V

0.5% to 100% of Nominal Range. Input volt-
age clamped to 12V through 1K ohms. Maxi-
mum of 0.15mA input current at1V input
voltage.

Mode Control

Voltage: open circuit or TTL logic 1
Current: short circuit or TTL logic 0

Available only when digitally activated through
Power-up setting.

Output Current

Analog Readback

0 to ±10 Volts corresponds to zero to

± Full Scale nominal output current

Output impedance of this signal is 2K Ohms.

External Protection Port
(see Table 2-4)

External Shutdown

Isolated input for shutdown of the

BOP (latched status)

Pulse width: 100

µ

S min.

Action delay: 100

µ

S max

Restore operation by cycling input power or
pressing RESET key.

External Shutdown

Flag

Isolated output indicating

shutdown status)

Action delay: 100

µ

S max

External On-Off

Flag or External

Trigger

Flag: Isolated output indicating

output on (enabled, STANDBY off) or

off (disabled, STANDBY on) status)

Trigger: Isolated trigger output for

external devices.

Flag:
LIST:SET:TRIG enables trigger function.
Flag action delay: 200 mS max

Trigger:
LIST:CLE disables trigger and restores flag.
Trigger output pulse duration:
settable between 0.25 to 34mS
Trigger output action delay: 100

µ

S max.

Trigger output active level: settable to either
“0” or “1.”

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION