16. Error

Codes

The controller records errors based on the communications links. When errors occur, an alarm will be generated.

Error Codes for the Evolution S

3

Error Code

Description

Explanation

LnE

Local Network Error

The Back-Up has lost Communications with the Master Controller.
NOTE: During this condition the Back-Up will run Cool 1 on a 5
minute timer.

LnO

Local Network

Override Error

The Master Controller has lost communications with one or more of the
Stage Units (PCB 168) connected to it. In this condition the Back-Up
takes control over the stages.