Manual No. 4801-3001 Rev 7-08

Secondary Sensing System Expansion

25 of 46

11. Controller Installation and Setup

11.1 Tools

Required

Mini Screwdriver

Standard Screwdriver

Wire Strippers

11.2 Installation

Instructions

1. Unpack system, and check that all components are present.

Qty Description

Qty

Description

1 S

3

Expansion Controller

1 Local Net Cable

3 Temperature

Sensors

1 Back-Up

Cable

1 Manual

2. Hang S

3

Expansion with four screws.

3. Make sure all power supplies are disconnected before breaking any wires, or reaching into the

system enclosure.

4. Open the S

3

Expansion and find all connections. Refer to wiring diagrams in Section 13 of this

manual.

5. Run temperature sensors out to locations inside the house. Be sure that the sensors are in a safe

location, free from any temperature influences (direct sunlight, water, etc.) Use care when
securing sensor wires so that the wire is not accidentally cut. Any short, or break in the wire will
cause improper sensor operation. Next, run the wires into the enclosure via the watertight
connector at the bottom of the box. The wires should be cut off and stripped. They next should
be attached to the terminal block in the positions marked Sen 1, Sen 2 and Sen 3. Note that the
sensors are not polarity sensitive, and it therefore makes no difference as to which wire goes to
which sensor terminal.

6. After the siren is mounted, it should be wired into the control box. This is done at the terminal

block locations labeled siren red and siren white. Note that polarity is important here and that the
red siren wire must be connected into the siren red terminal block position and the same for the
white wire. Note also, any 12VDC device that uses less than 1.5 Amps of current could be
connected in the siren’s place.

7. Connect wires from Alarm terminals to the alarm circuit or relay box. (See wiring diagrams in

Section 13.10 for locations of terminals.)

8. If using a modem, connect wires from Modem terminals to the modem circuit or relay box. (See

wiring diagrams in Section 13.10 for locations of terminals.)

9. If necessary, connect the S

3

Expansion to the Hired Hand Farm Manager Network. (See the

connections in Section 13.13 of this manual.)

10. Connect the AUX and CONTROL AUX connections. Refer to Section 13.11 diagram.

11. Remove jumpers for AUX & CONTROL connections if being used.

12. If connecting to an EV 3000/3001 controller, connect Local Net and Back-Up Network harnesses

setting in S

3

Expansion controller.

13. Wire Stage to Relay Card for Back-Up operation.

14. Set Stage Jumpers on Relay Cards in S

3

Expansion or EV 3000/3001. Refer to Section 13.9

diagram.

15. Connect Vent/Tunnel Overrides.

16. Connect AC Power. Refer to Section 13.5 diagram.

17. Program the S

3

Expansion. Refer to Section 6.