Using EZware-5000

91

To configure System Setting tab settings:

1. Startup language after redownloading the project: Select the language that the HMI is to use when

restarting after a download.

2. Execute init. MACRO when power on: When checked, the HMI will execute the selected macro on startup.

Available only when one or more macros exist in the project.

3. Auto logout: When checked, the HMI will automatically log out of security if no touchscreen activity is

detected during the specified interval. The time interval can range from 1 -256 minutes.

4. Hide system setting bar: When checked, the HMI will not display the button in the lower-right corner that

displays the System Setting toolbar. Local Bit LB9020 can be used to control the button. Set the bit to show

the button and clear the bit to hide the button.

5. Hide mouse cursor: When checked, the HMI will not display the mouse cursor. Local Bit LB9018 can be used

to control the mouse cursor. Set the bit to hide the cursor and clear the bit to show the cursor.

1010-1007, Rev. 10