102

EZware5000 Series Programming Manual

Please Note:

These files are captured by the HMI and stored in internal HMI memory, an attached SD card, or USB flash drive. You

must copy these files into your computer before using the EasyConverter utility. If you are running a project that is

capturing data log or event log files using the Offline Simulator, the EZware-5000 application automatically creates

new folders on your computer and creates the files.

Data log files are stored in a folder using the name that you assigned in the Data Sampling Object attribute box

(e.g.,C:\MapleSystems\EZ5000\datalog\History Data1\20100618.dtl)

Event log files are stored in an eventlog folder (e.g., C:\MapleSystems\EZ5000\eventlog\EL_20100625.evt).

Viewing an Event Log File (*.evt)

1. From the EasyConverter application, click File… Open and locate the Event Log file (*.evt).

2. [Creation time]: The text line below the creation time heading shows the date and time that the file was

initially created. Format is Day of Week, Month, Day of Month, Time (24Hr format), and Year.

3. [Data fields]: The text line below this header is used to label and identify each column of data under the

[Data] header. The Data fields header shows the event number, category of event, time event occurred in

24HR format, and the event (alarm) message recorded.

4. [Data]: This is where the actual data is recorded.

This is read only – the EasyConverter application does not allow any edits.

Viewing a Data Log File (*.dtl)

1. From the EasyConverter application, click File…Open and locate

the Data Log file (*.dtl). As the file is loaded,

the following popup window appears:

1010-1007, Rev. 10