EZware5000 Series Programming Manual

Recommended Format and Resolution

100% (1:1)

50% (1:2)

NTSC

720 x 480

360 x 240

PAL

720 x 576

360 x 288

A capture function allows capturing video images and storing them as *.jpg files on a USB flash drive or SD card. The

video capture is triggered by a PLC or local bit (OFF > ON) and can be configured to capture video once per second for

a period of time defined by the Record time. The time Before and time After define the time period (up to 10 seconds

each) before and after the trigger during which the video capture takes place. A buffer memory stores 10 seconds of

captured video when the capture function is enabled. The capture function continues uninterrupted even if the video

is in Pause mode.

Note: The Video In Object is available only on the X series models. It is standard on the HMI5150X and optional on the

HMI5104XH and HMI5121X.

Bar Graph

The Bar Graph Object is used to display register data in a bar graph display. It can be configured to have alarm

indicators using different colors on the bar graph to provide a warning when the value in the register is approaching a

maximum or minimum allowable value.

Meter Display

The Meter Display is used to display register data in an angular position on an analog-style meter. The scale (tick

marks) can be adjusted around the circumference of the meter and the pointer style can be changed. Scale values can

be assigned to the tick marks by assigning a span range (e.g., 0-100).

It can be configured to have alarm indicators using different color bars around the inside of the meter to provide a

warning when the value in the register is approaching a maximum or minimum allowable value.

Trend Display

The Trend Display Object is used to display real-time or historical data collected by the Data Sample Object on a line

graph. Up to 20 channels can be displayed on the graph with data collected from consecutive addresses, and with

different colors assigned to each channel (pen).

The Y-axis scaling is configured on the Channel tab with the Zero and Span fields (this defines the bottom and the top

of the Trend Display and should contain the range of values in the data sample). The X-axis scaling is configured on

the General tab with the Distance between data samples section. There are two options: Pixel (number of pixels

between samples) and Time (sets the width of the entire Trend Display in seconds).

In Real-time mode, data is displayed on the graph as it is generated. In History mode, data is plotted from data log

files saved in memory. A new data log file is created each day and can be displayed in the Trend Display by changing

the value in the History Control register. When the value in the History Control register is 0, the data for today is

displayed on the trend. When the value is 1, the data from yesterday is displayed, etc.

See Chapter 10 for more information on “Creating Trend Displays and Data Sampling Objects.”

1010-1007, Rev. 10