Page 90

Manual Mode by

PWM

The fan spins at the speed set in:

Fan PWM control

Auto Mode

D

EFAULT

The fan adjusts its speed using these settings:

Temp. Limit of OFF

Temp. Limit of Start

Fan Start PWM

Slope PWM 1

Temperature of Start [80]

The Temperature of Start field allows user to set the starting temperature using the + and

- keys.

Temperature of Off [75]

The Temperature of Off field allows user to set the off temperature using the + and –

keys.

Start PWM [30]

The Start PWM field allows user to set the start PWM speed using the + and – keys.

Slope (PWM duty) [4 (PWM duty)]

The Slope (PWM duty) field allows user to set the slope fan speed.

6.3.7 Serial Port Console Redirection

The Serial Port Console Redirection menu (BIOS Menu 11) allows the console

redirection options to be configured. Console redirection allows users to maintain a

system remotely by re-directing keyboard input and text output through the serial port.