Power ratings, Vacon nx_5 – mains voltage 380—500 v – TREND NX Variable Speed Drives User Manual
Page 35
18 • vacon
TECHNICAL DATA
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
4
4.2 Power
ratings
4.2.1
Vacon NX_5 – Mains voltage 380—500 V
High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min
Following continuous operation at rated output current, 150 % rated output current (IH)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IH)
Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min
Following continuous operation at rated output current, 110% rated output current (IL)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IL)
All sizes are available as IP21/NEMA1. Sizes FR4 to FR9 are additionally available as IP54/NEMA12.
Mains voltage 380-500 V, 50/60 Hz, 3~
Loadability
Motor shaft power
Low
High
380V supply
500V supply
Frequency
converter
type
Rated
continuous
current I
L
(A)
10%
overload
current
(A)
Rated
continuous
current I
H
(A)
50%
overload
current
(A)
Max
current
I
S
10%
overload
40°C
P(kW)
50%
overload
50°C
P(kW)
10%
overload
40°C
P(kW)
50%
overload
50°C
P(kW)
Frame
Dimensions and
weight
WxHxD/kg
NX 0003 5
3.3
3.6
2.2
3.3
4.4
1.1
0.75
1.5
1.1
FR4
128x292x190/5
NX 0004 5
4.3
4.7
3.3
5.0
6.2
1.5
1.1
2.2
1.5
FR4
128x292x190/5
NX 0005 5
5.6
6.2
4.3
6.5
8.6
2.2
1.5
3
2.2
FR4
128x292x190/5
NX 0007 5
7.6
8.4
5.6
8.4
10.8
3
2.2
4
3
FR4
128x292x190/5
NX 0009 5
9
9.9
7.6
11.4
14
4
3
5.5
4
FR4
128x292x190/5
NX 0012 5
12
13.2
9
13.5
18
5.5
4
7.5
5.5
FR4
128x292x190/5
NX
0016
5 16 17.6 12 18.0
24 7.5 5.5 11 7.5 FR5 144x391x214/8.1
NX 0022 5
23
25.3
16
24.0
32
11
7.5
15
11
FR5
144x391x214/8.1
NX 0031 5
31
34
23
35
46
15
11
18.5
15
FR5
144x391x214/8.1
NX 0038 5
38
42
31
47
62
18.5
15
22
18.5
FR6
195x519x237/18.5
NX 0045 5
46
51
38
57
76
22
18.5
30
22
FR6
195x519x237/18.5
NX 0061 5
61
67
46
69
92
30
22
37
30
FR6
195x519x237/18.5
NX 0072 5
72
79
61
92
122
37
30
45
37
FR7
237x591x257/35
NX 0087 5
87
96
72
108
144
45
37
55
45
FR7
237x591x257/35
NX 0105 5
105
116
87
131
174
55
45
75
55
FR7
237x591x257/35
NX 0140 5
140
154
105
158
210
75
55
90
75
FR8
291x758x344/58
NX 0168 5
170
187
140
210
280
90
75
110
90
FR8
291x758x344/58
NX 0205 5
205
226
170
255
336
110
90
132
110
FR8
291x758x344/58
NX 0261 5
261
287
205
308
349
132
110
160
132
FR9
480x1150x362/146
NX 0300 5
300
330
245
368
444
160
132
200
160
FR9
480x1150x362/146
NX 0385 5
385
424
300
450
540
200
160
250
200
FR10
595x2018x602/300
NX 0460 5
460
506
385
578
693
250
200
315
250
FR10
595x2018x602/300
NX 0520 5
520
572
460
690
828
250
250
355
315
FR10
595x2018x602/300
NX 0590 5
590
649
520
780
936
315
250
400
355
FR11
794x2018x602/370
NX 0650 5
650
715
590
885
1062
355
315
450
400
FR11
794x2018x602/370
NX 0730 5
730
803
650
975
1170
400
355
500
450
FR11
794x2018x602/370
NX 0820 5
820
902
730
1095
1314
450
400
500
500
FR12
1210x2017x602/600
NX 0920 5
920
1012
820
1230
1476
500
450
630
500
FR12
1210x2017x602/600
NX 1030 5
1030
1133
920
1380
1656
500
500
710
630
FR12
1210x2017x602/600
Table 4-1. Power ratings and dimensions of Vacon NX, supply voltage 380—500V.
Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to
or less than the factory default.
Note: The rated currents for FR10 to FR12 are all valid at an ambient temperature of 40 °C.