6. Inspection/Maintenance
(6)
Press the emergency-stop switch.
(7)
Set an adjustment jig (pin) in arm 1 or 2 to fix the arm at the reference position.
x Set the jig after confirming that the emergency-stop switch is pressed.
x Set the jig after adjusting the arm to the reference position, using the positioning mark label as a
guide.
x Arm 1 has a cover (not arm 2), which is fixed with setscrews. Remove the setscrews and detach
the cover before setting the jig.
x It is recommended that an adjustment jig be used to perform an absolute reset. With arm 1 or 2,
however, rotation data can be reset as long as a positioning accuracy of “center of positioning mark
label
r1 graduation” is ensured.
Arm 1
Positioning mark label
for arm 1
Positioning mark label
for arm 1
Positioning
mark label for
arm 2
Arm 2
Adjust arm 1 or 2 to a position
within ± 1 graduation of the center.
Reference position drawing
z Always press the emergency-stop switch before setting an adjustment jig. Failure to do so may
cause the robot to malfunction and result in a serious accident.
Warning