4 user wiring and piping – IAI America IX-NNC8040 User Manual
Page 32

26
5. Precautions for Use
5.4
User Wiring and Piping
The robot comes with standard cables and tubes that the user can use in a desired wiring/piping
configuration.
Quick joint
I6 (red)
Standard cable (5 m)
BK power cable (outside robot)
M cable (outside robot)
Quick joint
I6 (yellow)
User connector specifications
Rated voltage
3.0 V
Permissible current
1.1 A
Conductor size and number of wires
AWG 26 (0.15 mm
2
), 25 wires
Other
Twisted-pair cable (1 to 24), shielded
Piping specifications
Normal service pressure
0.8 MPa
I4 mm x I2.5 mm, 2 pieces
Dimensions (outer diameter x inner
diameter) and number of tubes
I6 mm x I4 mm, 2 pieces
Working medium
Air
ALM (indicator) specifications
Rated voltage
24 VDC
Rated current
12 mA
Illumination color
Red LED
Shape of Y-terminal
Spacer for user part installation
2.6
5.9
3.2
5.2
2 N
m or less
PG cable (outside robot)
Y-terminal at the end
To controller
Air tube
I4 (black, white)
I6 (red, yellow)
I4, I6 quick joint
I7
10
30 N or less
M4, depth 5
U cable
(outside robot)
(2 pcs. each)
BK SW
Brake-release
switch
Spacer for user
part installation
ALM indicator
User Connector
D-sub 25-pin
connector for user
wiring (socket),
fixing screw M2.6
Quick joint
I4 (black)
Quick joint
I4 (white)
External force applied to the spacers must not
exceed 30 N in the axial direction or 2 N
m in
the rotating direction (for each spacer).