background image

9. Installation

33

Reamed hole

Long hole

Tapped hole

9.1.3 N19SS,

N19SM

Mounting tapped holes are provided on the back of the base. Use these tapped holes for mounting the
actuator. The effective depth of the screws for mounting the base is as shown below. Exercise due caution
that the tip of the bolt does not stick out.
If an inappropriate bolt is used, the tapped holes may be damaged and/or the mounting strength of the
actuator may become insufficient, causing the degradation of precision and/or unexpected accidents.
Additionally, the reamed holes for the positioning pins are provided on the back of the base.

Tap diameter

Effective tap

length

Tightening torque

Reamed hole

Bolt bearing surface is

steel

Bolt bearing surface is

aluminum

M8 20

mm

31.3 N

ym (3.19 kgfym) 14

N

ym (1.43 kgfym)

‡8H7 depth 5 mm

About Tightening Screws

x Use hexagonal socket head bolts for the male screws used to install the base.
x Use of high-strength bolts of ISO-10.9 or greater is recommended.
x Ensure at least the following effective thread lengths for the bolts and male screws:

Male screw is made of steel

o Same as the nominal diameter

Male screw is made of aluminum

o Twice the nominal diameter