beautypg.com

Installation, continued, Platform interface cable wiring – Fairbanks PC2250 Utility Software User Manual

Page 80

background image

Section 3: Scale Installation

11/10

12

51233 Rev. 4

INSTALLATION, CONTINUED

8. Wire the scale cable to the proper type instrument, as shown in the chart below.
9. Once the scale platform is completely wired to the instrument, calibrate the unit.

─ Follow the appropriate instrument service manual to ensure a good calibration.

Platform Interface Cable Wiring

WIRE COLOR

FUNCTION

Black (

─) Excitation

Red (+)

Excitation

Yellow Shield

Green (+)

Signal

White (

─)Signal

This manual is related to the following products: