beautypg.com

Appendix i: data output formats – Fairbanks PC2250 Utility Software User Manual

Page 55

background image

6/12

55

51214 Rev. 7

Appendix I: Data Output Formats

General Notes:

= means carriage return character.
= line feed character.
= space character.
= end of transmission character.
<> = used to indicate individual characters for clarity only (not present in data
stream).

Fairbanks/ Toledo Continuous Output



A = Status Word A
B = Status Word B
C = Status Word C
W = Displayed Weight
T = Tare Weight

Leading zeros are not suppressed. The Continuous Computer Output is an
uninitiated, unrequested output that is transmitted at a fixed time interval.

Character String

Description

STX

Start of Text character : (02 Hex)

A

Status Word A

B

Status Word B

C

Status Word C

xxxxxx

Displayed Weight : x = Weight

(6 characters if grad size does not have a decimal point.)

(5 characters if the grad size does have a decimal point.

The decimal point is not sent as part of the character string.

xxxxxx

Tare Value : x = Tare

(6 characters if the grad size does not have a decimal point.)

(5 characters if the grad size does have a decimal point.

The decimal point is not sent as part of the character string

CR

Carriage Return Character : (0D hex)

CS

CheckSum Character : If enabled, this character consists of the last eight bits of the binary

sum of all characters transmitted up to this checksum character.


Status Word A
Bit #

Decimal Point or Zero Location

x00

x0

x

x.x

x.xx

x.xxx

x.xxxx

x.xxxxx

0

0

1

0

1

0

1

0

1

1

0

0

1

1

0

0

1

1

2

0

0

0

0

1

1

1

1

Increment Size

Count by 1

Count by 2

Count by 5

3

1

0

1

4

0

1

1

5

Always Logic 1

6

Always Logic 0

7

Parity Bit