Section 7: PC2250 Utility Software

6/12

46

51214 Rev. 7


INPUT

Single byte Commands can be sent from the network. Although the input is read as a
32 bit word only the least significant byte is used at this time. When the command is
sent and recognized it is entered into the 32 bit status byte in the least significant
command byte location. New commands can be transmitted after transmitting a
NULL command.

Recognized Commands

Print Stream (see Custom Format PC2250)
Print Format Stream; CR, SPACE, STX, ENQ or defined Poll Character
Tare: "A"
Print Ticket "p" / "P"
Zero "Z"
Change Gross Net Weigh Mode: "G"
Change Units: "U"

Debug

Data in the Anybus Module can be examined by operating the "START DEBUG"
button and stopped by operating the "STOP DEBUG" button.

The Write buffer contains three 32 bit words; Gross Weight, Tare Weight and the
Status Word and is the data sent to the network. The Contents of the Read buffer
which is the data received from the network is displayed as a 32 bit word.