Fieldbus Connections:


Profibus®



Pin

Signal

Description


3

B Line

Positive RxD/TxD, RS485 level

4

RTS

Request to Send

5

GND

Ground (Isolated)

6

+5 Bus Output

+5V termination power (Isolated, short circuit protected)

8

A Line

Negative RxD/TxD, RS485 level



DeviceNet™





Pin

Signal

Description


1

V-

Negative bus supply voltage

2

CAN_L

CAN low bus line

3

SHIEL D

Cable shield

4

CAN_H

CAN high bus line

5

V+

Positive bus supply voltage




Ethernet / IP


Use standard Cat 5 cable
(RJ45)

Output data can be verified using the PC2250 utility.

Additional information and EDS files are available at: http://www.hms.se/default.shtml