Ethernet / ip diagnostic led’s – Fairbanks PC2250 Utility Software User Manual
Page 26
![background image](/manuals/347091/26/background.png)
Section 4: Accessories
6/12
26
51214 Rev. 7
Ethernet / IP Diagnostic LED’S:
1: Network Status LED
2: Module Status LED
3: Link/Activity
4: Ethernet Interface (RJ 45) (Standard Cat 5 cable)
Network Status LED
State
Description
Off
Not online / No power
Green
Online, one or more connections established
Flashing Green
Online, no connections established
Red
Duplicate IP address, FATAL error
Flashing Red
One or more connections timed out
Module Status LED
State
Description
Off
No power
Green
Controlled by a scanner in Run state
Flashing Green
Not configures, or Scanner in idle state
Red
Major fault (EXCEPTION-state, FATAL error, etc.)
Flashing Red
Recoverable fault(s)
LINK / Activity LED
State
Description
Off
No link, no activity
Green
Link established
Green, flickering
Activity
Additional information and EDS files are available at: http://www.hms.se/default.shtml