beautypg.com

Fairbanks PC2250 Utility Software User Manual

Page 59

background image

Appendix I: Data Output Formats

6/12

59

51214 Rev. 7


UPS

Serial Data Output Format for UPS Worldship Software.


The instrument will transmit the following string of data.


Character Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

String 1

Gross Weight: X X X X . X X SP l/k b/g SP G/g R/r SP SP CR LF EOT




NOTES

1. Characters denoted by “X” are characters 0-9. Leading zeroes are replaced with
spaces (SP). Character 5 is a decimal point (HEX 2E).

2. Lower case “I” and “b” for Avoirdupois Units or “k” and “g” for Metrics Units.

3. The first weight character will be a minus (-), HEX 2D, If weight is negative.

4. Characters separated with an / denoted one of the characters will be transmitted.

5. Lower case gr in characters 12 &13 indicates scale motion. Upper case indicates
stable weight.

6. EOT, HEX 04 is transmitted in “HiCAP” condition.

7. Transmission will occur when a CR (Hex 0D) carriage return is received.