Appendix I: Data Output Formats
6/12
59
51214 Rev. 7
UPS
Serial Data Output Format for UPS Worldship Software.
The instrument will transmit the following string of data.
Character Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
String 1
Gross Weight: X X X X . X X SP l/k b/g SP G/g R/r SP SP CR LF EOT
NOTES
1. Characters denoted by “X” are characters 0-9. Leading zeroes are replaced with
spaces (SP). Character 5 is a decimal point (HEX 2E).
2. Lower case “I” and “b” for Avoirdupois Units or “k” and “g” for Metrics Units.
3. The first weight character will be a minus (-), HEX 2D, If weight is negative.
4. Characters separated with an / denoted one of the characters will be transmitted.
5. Lower case gr in characters 12 &13 indicates scale motion. Upper case indicates
stable weight.
6. EOT, HEX 04 is transmitted in “HiCAP” condition.
7. Transmission will occur when a CR (Hex 0D) carriage return is received.