beautypg.com

20 ma instrument setup – Fairbanks PC2250 Utility Software User Manual

Page 21

background image

Section 4: Accessories

6/12

21

51214 Rev. 7

4-20 mA Instrument Setup

Press the Units key for 3 seconds

NOTE:

Conditional upon service programming.


Gross / Net: Programming the weigh mode the output will track:
Select Gross or Net. The 4-20 mA analog output will track the selection. It will
continue to track the selection regardless of the currently selected weigh mode of the
FB2250. Press the ZERO key, then the UNITS key to toggle the available settings.
Press the ZERO key to enter the selection. Available selections are Gross or Net.

4.20 Lo: Programming the weight value associated with 4 mA: The display will
indicate 4.20 Lo: Press the ZERO key. The display will indicate the zero weight
“XXXXXX”. Press the UNITS key to increment the blinking digit, press the ZERO key
to advance to the next digit, repeat until entry is complete. After entering the least
significant digit, press the ZERO key. This weight entry will result in a 4 mA output.

4.20 Hi: Programming the weight value associated with 20 mA: The display will
indicate 4.20 Hi: Press the ZERO key. The display will indicate the maximum weight
“XXXXXX”. Press the UNITS key to increment the blinking digit, press the ZERO key
to advance to the next digit, repeat until entry is complete. After entering the least
significant digit, press the ZERO key. This weight entry will result in a 20 mA output.

This manual is related to the following products: