beautypg.com

Model jb3 - sizing and application data, Essential ordering information and data, Standard ul equipment and important options gas – Fulton VMP Webster Oil_Combo Burner User Manual

Page 10: Contact webster for complete information)

background image

(1)

STANDARD UL

EQUIPMENT

AND IMPORTANT OPTIONS

Gas

No. 2 Oil

No. 4 - 6 Oil Air

Atomized

STANDARD UL EQUIPMENT

AND IMPORTANT OPTIONS

Gas

No. 2 Oil

N0. 4 - 6 Oil Air

Atomized

Pressure At

om

iz

ed

Air

At

om

iz

ed

Pressure At

om

iz

ed

Air

At

om

iz

ed

General

Motor, Fan and Air Inlet Control

X

X

X

X

Gas Fuel

Main Manual Shutoff Valve

X

Air Flow Switch

X

X

X

X

Main Safety Shutoff Valve

X

(2)

Burner Mounted Control Panel,

Switch and Four Indicator Lights

X

X

X

X

Second Safety Shutoff Valve

X

Main Gas Regulator

X

Flame Safety Control

X

X

X

X

Gas Checking Valve

X

Ultra Violet Scanner

X

X

X

X

High and Low Gas Pressure Switches

X

Motor Starter with Overloads

X

X

X

X

Metering Valve (modulating systems)

X

Fuel Selector Switch

Duel Fuel Burners Only

Normal Open Vent Valve (above

12,500 MBH)

X

Ignition

Proven Gas Pilot Ignition

X

X

X

Oil Fuel

Oil Drawer Assembly with Diffuser

X

X

X

Pilot Solenoid Gas Valve

X

X

X

Oil Nozzles

X

X

X

Pilot Gas Regulator & Manual Valve

X

X

X

Oil Heater with Integral Thermostat

X

Pilot Gas Ignition Transformer

X

X

X

Remote Oil Pump

X

Opt.

Opt.

Two Safety Shutoff Valves

X

X

X

High Oil Temperature Switch

X

Low Air Atomizing Switch

X

Options

Inverted Housing

X

X

X

X

Low Oil Pressure Switch

X

X

X

Alternate Control Cabinet Positioning

X

X

X

X

Oil Pressure Gauge

X

X

X

Remote Control Panel

X

X

X

X

Oil Metering Valve

X

X

X

Fuel Metering CAM-NETIC II

X

X

X

X

Future Gas Combustion Head

Opt.

Opt.

Opt.

Posi-Control

X

X

X

X

Air Compressor

X

X

1. The configuration of each unit will vary with specific job requirements such as input rating, electrical specification and special agency approval codes.

The above chart shows those items standard to a basic burner plus a few options that may be added.

2. Indicator lights are “Power On”, “Call for Heat”, ”Fuel On” and ”Flame Fail”.

Model JB3 - Sizing and Application Data

(contact Webster for complete information)

Model

Number

Maximum

Furnace

Pressure

Burner Firing Capability Range

Burner

Motor

HP

Gas Train

#2 Oil Pump Motor HP

#4 - 6

Pump

Motor HP

Air

Compressor

Motor HP

Pipe

Size

Inlet

Press

Pressure

Atomizing

Air

Atomizing

Gas scfh

#2 Oil

gph

#4-6

Oil gph

JB3-30

3.5

1400 / 6300

10.2 / 45

10 / 42

3

2 1/2”

12 / 27”

1

Optional

Optional

2

JB3-50

3.5

1400 / 8300

11 / 59.2

10 / 55.3

5

3”

15 / 27”

1 1/2

Optional

Optional

2

JB3-75

3.5

1600 / 10500

12.3 / 75

11 / 70

7 1/2

3”

23 / 27”

1

Optional

Optional

2

JB3-100

3.5

1800 / 12600

20.3 / 90

12 / 84

10

3”

2-5 psi

1

Optional

Optional

2

The above maximum ratings are based on 0 furnace pressure, an altitude of 1000 feet, 90oF air temperature and 60 HZ electrical supply. Use the follow-

ing corrections for higher temperatures and altitude. Capacity by 17% for 50 Hertz.

Capacity decreases by 4% for each 1000 feet above 1000 foot altitude.

Capacity decreases by 6% for each 1 inch of furnace pressure.

Capacity decreases by 2% for each 10oF increase in air temperature over 90oF.

Gas input ratings based on 1000 BTU/cu ft. and 0.64 specific gravity. Sizes and pressure will vary with gas.

Oil input ratings are based on 140,000 BTU/gal. for ASTM #2 fuel oil and 150,000 BTU/gal for ASTM #4-6 fuel oil.

The vessel draft must be between -0.1 and +0.1 wc.

Essential Ordering Information and Data:

Power Supply - Confirm 120-60-1 for control circuit and electrical supply for burner motor(s) (voltage, frequency and phase).

Describe Boiler or Heater to be Fired - Including the manufacturer, model number, furnace pressure and furnace size.

Firing Rate - Define firing rates in MBH for gas and GPH for oil.

Fuel to be Burned - Type of gas and/or oil, including the BTU value.

Approval Agency - UL, FM, IRI (GE GAP), CSD-1, NFPA, Mil spec and local codes, if applicable.

Flame Safety Control Preferred - Honeywell or Fireye controls.

Gas Train Components Preferred - ASCO/ITT, Honeywell or Landis

Control System - ON-OFF, Low Fire Start, Low High Low, Modulation, Posi-Control

Required Options - Mounting plate, operating controls, limit controls, etc.

Model JB3 - Specification Data (12,600 MBH Maximum Input)

Page 10

Specification

JB Manual