Chapter 12

Peripheral Devices
N5102A Digital Signal Interface Module

Data Types

The following block diagram indicates where in the PSG signal generation process the data is injected
for input mode or tapped for output mode.

Output Mode

When using an ARB format, the data type is always Samples and no filtering is applied to the data
samples.The samples are sent to the digital module at the ARB sample clock rate.

For real- time formats, choosing Samples as the data type will send filtered samples to the digital
module at a rate between 50 MHz and 100 MHz. Selecting Pre- FIR Samples, sends unfiltered samples
to the digital module at a rate equal to the sample rate of the current format.

Input Mode

When the data type is Samples, the data samples coming through the digital module are injected at a
point that bypasses the filtering process.

If Pre- FIR Samples is selected, the data samples are injected before the filtering process. The
maximum rate will be determined by the selected filter. Refer to

Table 12- 7

.

Data

FIR

DACs

RF

Samples

Samples

Output

Samples

Samples

Pre-FIR

Mode

Filtering

I,Q

Modulator

LO

Input

Mode

Pre-FIR

PSG

Generator

I/Q