Liquid Controls SP3000 User Manual
Page 9

9
1.63
RELAY OUTPUTS
One relay is provided as a flow alarm and a second is provided for the other alarm conditions.
Each has the following specifications:
Type:
Dry contact, Form C
Contact Rating:
10A at 115/230 VAC/28 VDC
Typical Relay Output Schematics:
22
23
24
1.64
AUXILIARY POWER OUTPUT
Voltage:
24 VDC regulated and filtered
Isolation:
230 VAC max
Current:
0 to 100 mA
Protection:
Short Circuit Proof
1.7
RS-232 COMMUNICATIONS PORT
(Refer to RS-232 Addendum supplied with RS-232 option)
Connector:
25 Pin Sub-D
Input Impedance:
3000 ohms to 7000 ohms
Compliance Voltage:
Output: -25 to –5 (Mark); 5 to 25 (Space); Volts
Input:
-25 to –3 (Mark); 3 to 25 (Space); Volts
Protection:
Short Circuit Proof
Protocol:
8 bits, 1 stop bit
Parity:
None (Not Monitored)
Available Baud Rates:
300, 1200, 9600
RS-232 Connector Pin Out:
Printer Busy (11)
Pins 4 and 5 are jumpered together
Pins 6, 8, and 20 are jumpered together
Ground (7)
Recieve (2)
Transmit (3)
25 24 23 22 21 20 19 18 17 16 15 14
1
2
3
4
5
6
7
8
9
10
11
12
13
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)