Liquid Controls SP3000 User Manual
Page 7

7
1.52
RTD TEMPERATURE INPUTS
Compatible RTD type:
100 ohms Platinum
(a=0.00385; DIN 43-760 Calibration)
Configuration:
2, 3, or 4 wire
Excitation Current:
2mA typical
Max Fault Current:
15mA
Max Voltage on Sense Inputs:
50 VDC
Rejection of 50-60Hz signal:
40 dB (minimum)
(Automatically based on line frequency)
Raw Accuracy:
0.2% FS RTI
Temperature Range:
-323.5
o
to +1378.7
o
F
(-197.5
o
to +748.1
o
C)
Typical RTD Schematic:
~
2.2 VDC @ 2mA
A/D
1.5 F
1.5 F
20K
20K
100K
1
2
3
4
1.53
DIGITAL FLOW INPUT
Range:
3-30 VDC Pulse
Type:
Dry contact, opto-isolated or
voltage source
Max Input Frequency:
40kHz
Min. Pulse Width:
10
µsec (with 40kHz filter)
Thresholds:
OFF is less than 2.0V/ ON is
greater than 2.5V
Input Impedance:
Less than 30K ohms to ground
Excitation Voltage:
5VDC through 5.6K ohms resistor
Min. Frequency to maintain rate display: 1 Hz
Note: Totalizer counts all pulses down to 0 Hz
Typical Digital Pulse Input & Schematic:
1.5 F
5 VDC
@ 0.9 mA
5.6 K
39 K
100 K
+5 VDC
+5 VDC
16
17
18
COUNTER
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)