Liquid Controls SP3000 User Manual

Page 61

background image

61

SET BAUD

Format::

SET BAUD [nnnn] (CR)

Function:

Sets the baud rate to the value specified in nnnn. nnnn may be 300, 1200, or 9600. The
baud rate is immediately set to the value specified.

NOTE:

300 baud may cause undesirable delays in communication.


Example:

SET BAUD 1200 (CR)


SET EXCEPTION:

Format::

SET EXCEPTION [ON, OFF] (CR)

Function:

Turns Exception Reporting ON or OFF.


Exception Reporting is a function that allows the operator to view different parameters that have recently gone into
alarm condition (See section on Exception Reporting in this chapter).

Example:

SET EXCEPTION on (CR)


SET LIST:

Reference:

See Section 8.2

Format::

SET LIST n n n n (CR)

Where n is the number of an item on the display list

Function:

The SET LIST command is used to set up a display list which can be periodically printed at
a remote terminal or printer. The user would first type EXAMINE LIST to obtain a list of
available display items, and would then use the SET LIST command to enter them into a
printable list of items.


Example:

MFC01 Examine List (CR)

[SELECT items from this list:]


[1]

Time & Date

[2]

Flow rate

[3]

Totalizer

[4]

Temperature

[5]

Pressure

[6]

Uncompensated Flow

[7]

Raw Flow (Chan 3)

[8]

Raw Temp. (Chan 1)

[9]

Raw Press. (Chan 2)

[10]

Analog Output

MFC01


NOTE: List will vary depending on Hardware and Computation Selected.

Then, the user selects time, flow rate, totalizer, and pressure by typing:

MFC01 SET LIST 1 2 3 5 (CR)

Then when the instrument is running and the PRINT INTERVAL is greater than 0.24999 minutes the instrument will

show:

11:55:52 Monday

April 28, 1992

Flow Rate

10,000 SCFM

Totalizer

1245.000 cu-ft

Pressure

12.000 PSIG