Liquid Controls SP3000 User Manual
Page 41

41
8.1
SHOW DATA
This menu item will start the data list scrolling on the LCD display. The order of display for up to 16 items
can be designated in the “Setup data display?” menu. Each item can be displayed more than once in the
scan list. Each item will be displayed for approximately two seconds. If an item requires longer display
time, it may be selected for consecutive display points.
The parameters available for display selection (from a total of 19) are dependent upon the Computation
and Hardware setup. The system automatically determines the data available for display based on the
programmed parameters.
DISPLAY DATA DESCRIPTIONS:
1.
Time and Date
Current time and date
2.
Flow Rate
Filtered & Compensated with engineering units
3.
Mass Flow
Filtered & Compensated with engineering units
4.
Heat Flow
Filtered & Compensated with engineering units
5.
Totalizer
Compensated accumulated flow with engineering units
6.
Totalizer
(Mass) Compensated accumulated flow
7.
Heat Totalizer
Compensated accumulated heat flow
8.
Temperature
Filtered & Scaled temperature in degrees
9.
Pressure
Filtered & Scaled pressure in units of measurement
10.
Uncompensated Flow
Filtered but not compensated with engineering units
11.
Raw Flow (Channel 3)
Analog value of flow input
12.
Raw Pressure (Channel 2) Raw analog value of pressure input
13.
Raw Temperature (Channel 1)
Raw analog value of temperature input
14.
Raw RTD Input 1
Raw analog value of RTD input in mA
15.
RTD Ohms (Channel 1)
Resistance of RTD
16.
Analog Output
Output value in mA
17.
Specific Volume
Current specific volume from Steam Tables
18.
Specific Heat
Current specific heat from Steam Tables
19.
Flow Frequency
Raw input pulse frequency
8.1.1
DISPLAY DATA SETUP
Running...
Show Data?
Running...
Go to Standby?
Running...
Setup data display?
Select item #1
Time & Date? Press to advance the list of data available for display
Press to backup the list of data available for display
Press to select the data for display. The item # will increment as each selection is
made
Continue to advance or backup the list and select desired data for display
NOTE: Up to 16 display items may be selected. Pressing the button exits the routine and returns to “Show Data?”
when the desired number of display items is entered. If 16 items are entered, the unit exits the routine and
returns to “Show Data?” upon entering item 16.
(DISREGARD IF RS-232 OPTION IS NOT INSTALLED IN UNIT)
A
A
ENT
B
ENT
A
C