EXAMINE COMMAND:
Reference:
See Section 8.4 through 8.6
Function:
The EXAMINE commands are used to examine setup information about the instrument.
EXAMINE COMPUTATIONS
EXAMINEs if computations that will be used have been set for Volume, Mass, or Heat for Gas, Liquid, or Steam.
EXAMINE UNITS
EXAMINEs which engineering unit has been selected (English or Metric)
EXAMINE HARDWARE
EXAMINEs specific hardware settings of the instrument, and tells if instrument is locked or unlocked.
SPECIFIC EXAMINE COMMANDS
In addition to the EXAMINE Commands listed previously, there are SPECIFIC EXAMINE COMMANDS that allow
specific parameters to be EXAMINEd remotely.
REQUIRED WORDS:
OPTIONAL WORDS:
EXAMINE temperature low scale
input
EXAMINE temperature high scale
input
EXAMINE reference temperature
EXAMINE temperature low alarm
EXAMINE temperature high alarm
EXAMINE pressure low scale
input
EXAMINE pressure high scale
input
EXAMINE barometric
pressure
EXAMINE pressure low alarm
EXAMINE pressure high alarm
EXAMINE k
factor
EXAMINE k1
factor
EXAMINE z
factor
EXAMINE gravity
specific
EXAMINE c
thermal expansion
EXAMINE heat
specific
EXAMINE point
EXAMINE flow low scale
input
EXAMINE flow high scale
input
EXAMINE delta P high
input
EXAMINE delta P low
input
EXAMINE flow cutoff
EXAMINE flow filter
EXAMINE flow low alarm
EXAMINE flow high alarm