The instrument will not understand this command and will give a “Syntax Error” message. The problem with this
command is that it does not specify to setup alarm or scale.
A more subtle type of problem with a command is as follows:
SET flow alarm to 100 (CR)
This phrase will also generate a “Syntax Error” because it is unclear whether the LOW flow alarm or the HIGH flow
alarm is to be accessed.
Reference: See Section 3.5
REQUIRED WORDS:
OPTIONAL WORDS:
SET temperature low scale
input
SET temperature high scale
input
SET reference temperature
SET temperature low alarm
SET temperature high alarm
SET pressure low scale
input
SET pressure high scale
input
SET barometric
pressure
SET pressure low alarm
SET pressure high alarm
SET k
factor
SET k1
factor
SET z
factor
SET gravity
specific
SET c
thermal expansion
SET heat
specific
SET point
This command is followed by three numbers. The point number, the uncompensated flow (pulse or analog) and
then the K factor.
SET flow low scale
input
SET flow high scale
input
SET delta P high
input
SET delta P low
input
SET flow cutoff
low
SET flow filter
input
SET flow low alarm
SET flow high alarm
SET low output
flow scale
SET high output
flow scale
SET scale output
flow digital factor pulse
SET id (See special section on SET ID; pg. 7)
SET baud (See special section on SET BAUD; pg. 7)
SET print interval