beautypg.com

Appendix ii, Appendix iii – Liquid Controls SP3000 User Manual

Page 51

background image

51


Appendix ii

CONVERSION TABLE

Convert from:

ENGLISH

X (CONVERSION FACTOR)

= METRIC

ft

3

/min

X 1.69902

= m

3

/h

GPM

X 0.063085

= liters/sec

lbm/h

X 0.45359

= kg/h

Btu/h

X 0.01757

= kW

Btu/h

X 15.12

= kcal/h

Btu/h

X 0.0633034

= MJ/h

ft

3

X 0.028317

= m

3

gals

X 3.785109

= liters

lbm

X 0.45359

= kg

Btu

X 0.0002928

= kWh

Btu

X 0.252

= kcal

Btu

X 0.001055056

= MJ

Deg F

X (0.555555) + (-17.7776)

= Deg C

PSIG

X 6.894757

= kPa

PSIG

X 0.070306

= kg/cm

2

PSIG

X 0.06894757

= bar

GPM

X 0.01337

= ACFM

ACFM

X 7.4805

= GPM



Appendix iii


PROGRAMMING ERROR MESSAGES

These messages occur when attempting to go to the running mode or entering a value that is not allowed.

NOTE: All Error messages are followed by the phrase: “Push ENT to continue” Pressing ENT does not correct the error nor

access the point of error. The menu must be accessed and correct data entered.


MESSAGES

TEMP HI-LO LIM ERR:

Temperature input parameters have not been entered or a low limit is higher than a high limit.

PRESS HI-LO LIM ERR: Pressure input parameters have not been entered or a low limit is higher than a high limit.
FLOW HI-LO LIM ERR:

Flow input parameters have not been entered or a low limit is higher than a high limit.

NEED MORE FLOW INFO:All of the flow input parameters have not been entered.
Z FACTOR ERROR:

Z factor has been set to zero; change to any number greater than zero.

SCALE FACTOR ERROR: K factor has been set to zero; change to any number greater than zero.
NO VALUE STORED YET:The unit has a null value in it from initialization. Enter a value.
BAD LOCK CODE:

Attempt has been made to enter 00000 as the lockout code; use any number other than 00000 to
lock out computer. In the lock confirming step, the 5 digit code entered is not the same as the 5
digits initially entered.

SYNTAX ERROR:

Time or date was not entered in proper format. Refer to section 7.

BAD TIME VALUE:

Invalid time entered. Refer to section 7.

BAD DATE VALUE:

Invalid date entered. Refer to section 7.

BAD ID VALUE:

RS-232 option only. Invalid unit ID entered. Refer to RS-232 instructions.