51
Appendix ii
CONVERSION TABLE
Convert from:
ENGLISH
X (CONVERSION FACTOR)
= METRIC
ft
3
/min
X 1.69902
= m
3
/h
GPM
X 0.063085
= liters/sec
lbm/h
X 0.45359
= kg/h
Btu/h
X 0.01757
= kW
Btu/h
X 15.12
= kcal/h
Btu/h
X 0.0633034
= MJ/h
ft
3
X 0.028317
= m
3
gals
X 3.785109
= liters
lbm
X 0.45359
= kg
Btu
X 0.0002928
= kWh
Btu
X 0.252
= kcal
Btu
X 0.001055056
= MJ
Deg F
X (0.555555) + (-17.7776)
= Deg C
PSIG
X 6.894757
= kPa
PSIG
X 0.070306
= kg/cm
2
PSIG
X 0.06894757
= bar
GPM
X 0.01337
= ACFM
ACFM
X 7.4805
= GPM
Appendix iii
PROGRAMMING ERROR MESSAGES
These messages occur when attempting to go to the running mode or entering a value that is not allowed.
NOTE: All Error messages are followed by the phrase: “Push ENT to continue” Pressing ENT does not correct the error nor
access the point of error. The menu must be accessed and correct data entered.
MESSAGES
TEMP HI-LO LIM ERR:
Temperature input parameters have not been entered or a low limit is higher than a high limit.
PRESS HI-LO LIM ERR: Pressure input parameters have not been entered or a low limit is higher than a high limit.
FLOW HI-LO LIM ERR:
Flow input parameters have not been entered or a low limit is higher than a high limit.
NEED MORE FLOW INFO:All of the flow input parameters have not been entered.
Z FACTOR ERROR:
Z factor has been set to zero; change to any number greater than zero.
SCALE FACTOR ERROR: K factor has been set to zero; change to any number greater than zero.
NO VALUE STORED YET:The unit has a null value in it from initialization. Enter a value.
BAD LOCK CODE:
Attempt has been made to enter 00000 as the lockout code; use any number other than 00000 to
lock out computer. In the lock confirming step, the 5 digit code entered is not the same as the 5
digits initially entered.
SYNTAX ERROR:
Time or date was not entered in proper format. Refer to section 7.
BAD TIME VALUE:
Invalid time entered. Refer to section 7.
BAD DATE VALUE:
Invalid date entered. Refer to section 7.
BAD ID VALUE:
RS-232 option only. Invalid unit ID entered. Refer to RS-232 instructions.