Liquid Controls SP3000 User Manual
Page 29

29
3.552 PROGRAMMING EXAMPLE: `Flowchart: Digital Pulse – Sixteen Point
**NOTE: This is an example of 16 point programming using calibration data for turbine Serial No. 107221. (See
next page) Actual Calibration data must be entered for the specific turbine flowmeter used with the unit.
Select Setup item:
Flow input?
Linearize
16 point?
Enter point
Freq 09?
Press 834
Press
Enter point
Freq 01?
Press 0
Press
Freq 09? 834.0000
K-Factor 09?
Press 2274834
Press
Freq 01? 0.0000
K-Factor 01?
Press 1383067
Press
Enter point
Freq 10?
Press 948
Press
Enter point
Freq. 02?
Press 32
Press
Freq 10? 958.0000
K-Factor 10?
Press 2303039
Press
Freq 02? 32.0000
K-Factor 02?
Press 1383067
Press
Enter point
Freq 11?
Press 1058
Press
Enter point
Freq 03?
Press 148
Press
Freq 11? 1058.0000
K-Factor 11?
Press 2323958
Press
Freq 03? 148.0000
K-Factor 03?
Press 2160356
Press
Enter point
Freq 12?
Press 1290
Press
Enter point
Freq 04?
Press 259
Press
Freq 12? 1290.0000
K-Factor 12?
Press 2384127
Press
Freq. 04? 259.0000
K-Factor 04?
Press 2161185
Press
Enter point
Freq 13?
Press 1514
Press
Enter point
Freq 05?
Press 377
Press
Freq 13? 1514.0000
K-Factor 13?
Press 2417309
Press
Freq 05? 377.0000
K-Factor 05?
Press 2203285
Press
Enter point
Freq 14?
Press 1741
Press
Enter point
Freq 06?
Press 492
Press
Freq 14? 1741.0000
K-Factor 14?
Press 2440122
Press
Freq 06? 492.000
K-Factor 06?
Press 2224646
Press
Enter point
Freq 15?
Press 1966
Press
Enter point
Freq. 07?
Press 601
Press
Freq 15? 1966.0000
K-Factor 15?
Press 2458372
Press
Freq 07? 601.000
K-Factor 07?
Press 2235430
Press
Enter point
Freq 16?
Press 2195
Press
Enter point
Freq 08?
Press 723
Press
Freq 16? 2196.0000
K-Factor 16?
Press 2479318
Press
Freq 08? 732.0000
K-Factor 08?
Press 2256791
Press
Gas Compressibility
Z Factor
NOTE: To view the previously entered value at any data entry point, press ENT. The stored value will display. If the display value doesn’t need
to be changed, press ENT. The value will be retained and the unit will automatically advance to the next data entry point. If the value needs to
be changed, press CLR. Press the number keys to display the desired value to be entered, then press ENT. The value will be stored and the
unit will automatically advance to the next data entry point.