1.

115 VAC Neutral

2.

115 VAC Neutral Output To Slave Operator

3.

115 VAC Power Input

4.

115 VAC Motor Power (Open)

5.

115 VAC Motor Power (Close)

6. Not

used

7.

24 VAC Radio Receiver Power Only (250 ma. maximum)

8.

12 VAC Magnetic Counter Power Only (150 ma. maximum)

9.

PULSE 1 Input From Master Operator

10.

PULSE 2 Input From Slave Operator

11.

SINGLE BUTTTON ACTIVATION INPUT 1

When gate is closed, input will open gate.

When gate is open and auto close timer is turned on, input will re-set and hold timer.

When gate is open and auto close timer is turned off, input will close gate.

When gate is closing, input will reverse gate.

12.

SINGLE BUTTON ACTIVATION INPUT 2 / OPEN LOOP LOGIC OUTPUT

If SW 1,switch 3 is ON, this input is identical to Single Button Activation Input 1.

If SW 1, switch 3 is OFF, this terminal becomes the logic output of the OPEN loop
detector.

13.

OPEN INPUT - Use with DoorKing 3 button control station only (P/N 1200-006).

14.

CLOSE INPUT - Use with DoorKing 3 button control station only (P/N 1200-006).

15.

REVERSE (SAFETY) INPUT / SHADOW INPUT

When gate is closed, this input has no affect on the gate operator.

When gate is open and auto close timer is turned ON, input will re-set and hold timer.

When gate is open and auto close timer is turned OFF, input will prevent gate from
closing.

When gate is closing, input will reverse gate if SW 2, switch 5 is OFF.

When gate is closing, input has no affect on the gate operator if SW 2, switch 5 is
ON.

16. DRY

RELAY

CONTACT

Operation of relay is dependent on setting of SW 1, switches 1 and 2. Relay contacts
can be set for Normally Open (NO) or Normally Closed (NC) operation. Contact
rating is 1 amp maximum at 24 Volts.

17. DRY

RELAY

CONTACT

18.

MAGNETIC LOCK OUTPUT

With SW 1, switch 1 ON and switch 2 OFF, 24-volt magnetic lock power is provided
constantly except when the gate is opening or open.

19.

LOW VOLTAGE COMMON

20.

LOW VOLTAGE COMMON