Controls must be far enough from the gate so that the user is prevented from coming in
contact with the gate while operating the controls. Outdoor or easily accessible controls
should have a security feature to prevent unauthorized use.

• Connect optional control devices to the master operator terminal strip as shown in Figure 25.

Be sure that all electrical connections are made in accordance with local electrical codes.
Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet. Use a low voltage
surge suppresser, DoorKing P/N 1878-010 if low voltage wire runs exceed 1000 feet. All
inputs to the terminal strip must be NORMALLY OPEN.

• Standard reversing input (term 15) only functions while the gate is in the closing cycle and

should not be used as an input for a secondary entrapment protection device for the open
gate cycle. See section 2.2.2 for secondary entrapment protection device wiring.

• Do not power any devices from the circuit board other than a low voltage radio receiver.
• Three-button

control

station must be DoorKing P/N 1200-006 only. Others will not work.

• If magnetic lock is used, refer to section 2.4.

2.2 CONTROL

WIRING

Figure 25

11

12

13

14

15

16

17

18

19

20

Fire

Dept

OPEN

CLOSE

STOP

Push
Button

Keyswitch

Lock
Boxes

Telephone
Entry
Systems

Digital
Keypad

Card
Readers

3 Button

Control

Photocell

Single Button
Activation

Single Button
or Loop Logic

Open Only

Close Only

Std Safety

Relay

Relay

Magnetic Lock
Power

Common

Common