3 - 42
Table 3-30 Offset Mode Example
CP
Parameter Name Value Remarks
CP-84
Analog Input
Allocation
CP-21
Follower
Engineering Units
CP-34
Max RPM Feedback
CP-31
PPR Feedback
CP-33
Max RPM Lead
CP-30
PPR Lead
CP-75
Offset Null
CP-76
Offset Authority
CP-77
Offset Polarity
Allocates The analog input as the
Offset input.
This is the Engineering Unit value
that is present if the lead and
feedback at max RPM.
The maximum operating RPM of
the feedback shaft.
The resolution of the feedback
sensor.
The maximum operating RPM of
the lead shaft.
The resolution of the lead
sensor.
The neutral dancer pot position.
The authority of the dancer offset
term.
The offset is subtracted from the
scaled reference.
3
1.000
1800
60
1800
60
60.0
15.0
2