Danger, G - 4 – CONTREX MLP-Drive User Manual
Page 194

G - 4
DANGER
This diagram is for conceptual purposes only!
Use safety equipment.
Make wiring connections carefully.
Incorrect use of equipment or connections
can cause injury or death.
LEAD_FQ
FDBK_FQ
COM
RUN
JOG
R–STOP
F–STOP
COM
MST / FOL
SETPT
SCRL_UP
SCRL_DWN
COM
V_DO
DIG_OUT1
DIG_OUT2
COM
ANAL_IN
COM
J1
J3
T / R +
T / R –
COM_AUX
RS485
COMM
A1 +
A2 -
L1
NEUT
GND
PE
AC
POWER
MOTOR
ARM
I / O
PWR
FREQ
INPUTS
DIGITAL
INPUTS
J4
DIGITAL
OUTPUTS
5V_DI
COM
J2
Run
Jog
R-Stop
F-Stop
Setpoint
Select
Feedback
Frequency
Run
Jog
R-Stop
F-Stop
Master/
Follower
Setpoint
Select
Feedback
Frequency
DC PM
Motor
Lead
Frequency
5V Ext
Pwr Supply
+
–
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
ANAL
IN
AUX
PWR
5V
COM_AUX
1
2
3
1
2
J5
LEAD_FQ
FDBK_FQ
COM
RUN
JOG
R–STOP
F–STOP
COM
MST / FOL
SETPT
SCRL_UP
SCRL_DWN
COM
V_DO
DIG_OUT1
DIG_OUT2
COM
ANAL_IN
COM
J1
J3
T / R +
T / R –
COM_AUX
RS485
COMM
AC
POWER
I / O
PWR
FREQ
INPUTS
DIGITAL
INPUTS
J4
DIGITAL
OUTPUTS
5V_DI
COM
J2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
ANAL
IN
AUX
PWR
5V
COM_AUX
1
2
3
1
2
J5
1
2
1
2
1
2
3
4
5
A2 -
A1 +
DC PM
Motor
A2 -
A1 +
A1 +
A2 -
L1
NEUT
GND
PE
MOTOR
ARM
1
2
3
4
5
Figure G-4 Two Channel Start/Stop - Lead/Follower Logic