Clear-Com BS850 (Last time buy) User Manual
Page 20
Frequency Scan:
Connect a Beltpac to the BELTPAC CONFIG
connector on the front panel of the base station to
enable scanning of base transmit frequencies.
In this operation, the Beltpac and base station
receivers are scanned to find the cleanest group of
frequencies for the base station to transmit on, and
they are assigned to Tx1 and Tx2 in the base
station. Also, based on the number of receivers in
the system (up to 12), it determines the best group
of frequencies for the base station(s) to receive on.
Those frequencies are distributed (first-come,
first-served) to the Beltpacs (assuming 16 Beltpacs
will be used) as Beltpac transmit frequencies.
Beltpac receiver frequencies are always the same
as the base station Tx1 and Tx2 frequencies.
Beltpac frequency settings will not be operational
until they are uploaded to the Beltpacs, which
should be done after completion of Beltpac
configuration settings.
These settings will automatically be saved to File 1
as active settings for the base station until the
frequencies are scanned again. They can also be
saved to another file name for future use.
To begin frequency scanning, press the ENTER
button. A warning message will be displayed.
Press CANCEL to clear the message. Press
ENTER again to start the scan.
Base Station Identifier:
Use the arrow buttons and control knob to assign
an identifying name or number of up to nine
characters to the base station.
To enable the display of the name as a screen
saver when other operations are not being
performed, check the Enable box. The base name
will be displayed a few minutes after the last
button has been pressed. Once the screen saver is
active, press Cancel to clear it.
Base Station Display Contrast Level:
Use the control knob to adjust the base station
display screen contrast level.
NOTE: In a Master/Slave configuration, always
perform frequency scans at the Master base. The
Master will automatically save its settings in File 1.
However, the Slave(s) will not. Slave settings must
be saved manually at each Slave, or with PC850.
17