SCA FILE EXAMPLE
provides an example of an SCA file.
17
Performance Primitive
Notifications
bit 7 = segment anomaly
bit 6 = CRC anomaly
bit 5 = segment defect
bit 4 = loss of sync word defect
bit 3 = SNR margin defect
bit 2 = loop attenuation defect
bit 1 = loss of sync word failure
bit 0 = tip/ring reversal
18
SHDSL ES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
19
SHDSL SES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1A
SHDSL UAS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1B
SHDSL CVC 15 Minute Alarm
Threshold
0 = Disabled
1 to 65535 = threshold in seconds
1C
SHDSL LOSWS 15 Minute
Alarm Threshold
0 = Disabled
1 to 900 = threshold in seconds
1D
Line Rate Control
0 = STU-C
1 = STU-R
1E
SHDSL OS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1F
Outage Auto-Retrain
0 = Disabled
1 = Enabled
20 - 27
Reserved Options for future use
Table B-5. LocSTULineProvisioning (Continued)
Column
Option
Values