ADTRAN Total Access 1240 User Manual
Page 141
Appendix B, SCA File Format - SCA Format
61179605L5-5B
B-5
7
Annex
0 = A
1 = B
2 = A/B
8
LineProbing
0 = Disabled
1 = Enabled Current Condition
2 = Enabled Worst Case
9
Repeater Mode
0 = Terminator
1 = Repeater
A
M-pair Mode
0 = 2-wire
1 = 4-wire
2 = Mpair
B
Number of Pairs (Mpair mode
only)
2 pairs ONLY
C
Valid Data Slots (Mpair mode
only)
Bit-wise representation of the ports to be physically
bonded:
bit 0 - pair 1
bit 1 - pair 2
bit 2 - pair 3 (NOT VALID)
bit 3 - pair 4 (NOT VALID)
D
Min Line Rate
N = 3 to 36, where rate = N × 64k + 8k
E
Max Line Rate
N = 3 to 36, where rate = N × 64k + 8k
F
Current Line Rate
N = 3 to 36, where rate = N × 64k + 8k
10
Min Sub Rate
N = 0 to 7, where rate = Line Rate + (N × 8k)
11
Max Sub Rate
N = 0 to 7, where rate = Line Rate + (N × 8k)
12
PMMS Margin CC
–10dB to 20dB
13
PMMS Margin WC
–10dB to 20dB
14
Clock Mode
0 = Plesio
1 = Plesio w/Reference
2 = Sync
3 = Sync Hybrid
15
Framing Mode
0 = Frame Plesio
1 = Frame Sync
2 = Frame Transparent
16
F-bit notifications
bit 3 = segment defect: 1 = normal, 0 = segd alarm
bit 2 = power status: 1 = normal, 0 = rem loss of power
bit 1 = segment anomaly: 1 = normal, 0 = sega alarm
bit 0 = loss of signal: 1 = normal, 0 = loss of signal
Table B-5. LocSTULineProvisioning (Continued)
Column
Option
Values