beautypg.com

Description of the name plate, Available versions – Burkert Type 8041 User Manual

Page 9

background image

7

Description

When the fluid flows over them, a voltage is measured between the
two electrodes. This voltage is proportional to the fluid velocity.

Fig. 1: Operating principle of the flow sensor

5.3.

Description of the name plate

FLOW:8041- IND LONG SST
18-36V —/220mA 4-20mA REL:230VAC~/3A CO

SN/ 2135

00552780

W47MG

Made in France

1

3

2

5

6

7

8

9

11

4

10

Fig. 2: Name plate of the device (example)

1.

Power supply / Max. consumption.

2.

Measured value and type of the device

3.

Specification of the flow sensor

4.

Compact housing

5.

Manufacturing code

6.

Relay data

7.

Conformity logo

8.

Warning: Before using the device, take into account the tech-
nical specifications described in these operating instructions.

9.

Current output

10.

Serial number

11.

Order code

5.4.

Available versions

Flow
sensor

Material

Order code

Flow sensor

Seal of the flow

sensor

Short

PVDF

FKM

558064

Long

558065

Short

Stainless steel

FKM

552779

Long

Stainless steel

FKM

552780

Clamp

Stainless steel

EPDM or FEP

1)

564688

1)

Ordered separately. See chap. 11.

English