Description of the name plate, Available versions – Burkert Type 8041 User Manual
Page 9
7
Description
When the fluid flows over them, a voltage is measured between the
two electrodes. This voltage is proportional to the fluid velocity.
Fig. 1: Operating principle of the flow sensor
5.3.
Description of the name plate
FLOW:8041- IND LONG SST
18-36V —/220mA 4-20mA REL:230VAC~/3A CO
SN/ 2135
00552780
W47MG
Made in France
1
3
2
5
6
7
8
9
11
4
10
Fig. 2: Name plate of the device (example)
1.
Power supply / Max. consumption.
2.
Measured value and type of the device
3.
Specification of the flow sensor
4.
Compact housing
5.
Manufacturing code
6.
Relay data
7.
Conformity logo
8.
Warning: Before using the device, take into account the tech-
nical specifications described in these operating instructions.
9.
Current output
10.
Serial number
11.
Order code
5.4.
Available versions
Flow
sensor
Material
Order code
Flow sensor
Seal of the flow
sensor
Short
PVDF
FKM
558064
Long
558065
Short
Stainless steel
FKM
552779
Long
Stainless steel
FKM
552780
Clamp
Stainless steel
EPDM or FEP
1)
564688
1)
Ordered separately. See chap. 11.
English