beautypg.com

Technical data, Conditions of use, Conformity to standards and directives – Burkert Type 8041 User Manual

Page 10: Mechanical data

background image

8

Technicaldata

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature

-10 °C...+60 °C

Air humidity

< 80%, non condensated

Protection class acc. to
EN 60529

IP65, with cable connected and
cable gland tightened and cover
screwed on to the electronic module

Degree of pollution

Degree 2 acc. to EN 61010-1

Installation category

Category I acc. to EN 61010-1

Max height above see level

2000 m

6.2.

conformity to standards and
directives

The device conforms to the EC directives through the following
standards:
• EMC: EN 50081-1, EN 61000-6-2
• LVD: EN 61 010-1
• Pressure: article 3§3 of the Pressure Directive 97/23/CE. Acc. to

the Pressure Directive 97/23/CE: the device can only be used in
the following cases (depending on the max. pressure, the DN of
the pipe and the fluid)

type of fluid

conditions

Fluid group 1, par. 1.3.a

Forbidden

Fluid group 2 par. 1.3.a

DN ≤ 32
or DN > 32 and PNxDN ≤ 1000

Fluid group 1 par. 1.3.b

PNxDN ≤ 2000

Fluid group 2 par. 1.3.b

DN ≤ 200
or PN ≤ 10
or PNxDN ≤ 5000

6.3.

mechanical data

Table 1 : Wetted parts

part

material

Holder of the flow sensor

PVDF or stainless steel
1.4404 / 316L

Electrodes

Stainless steel
1.4404 / 316L

Clamp (only clamp version)

Stainless steel
1.4404 / 316L

Earthing ring (only if flow sensor holder in
PVDF)

Stainless steel
1.4404 / 316L

Holder of the electrodes (only if flow
sensor holder in stainless steel)

PEEK

Seal of the flow sensor (version with
G2" nut)

FKM (FDA approved)

English

Type 8041