INstallation
Example:
-
Specification:
if
the
nominal
flow
rate
is
10
m
3
/hthe
ideal
flow
velocity
is
between
2
and
3
m/s
-
Solution:
intersection
between
flow
rate
and
flow
velocity
in
the
graph
gives
the
appropriate
pipe
diameter,
DN40
(or
DN50
for
the
asterisked
fittings)
.
*
For
the
fittings:
-
with
external
thread
connections
acc.
to
SMS
1145
;
-
with
weld
end
connections
acc.
to
SMS
3008,
BS
4825
/
ASME
BPE
or
DIN
11850
Range
2;
-
with
Clamp
connections
acc.
to
SMS
3017
/
ISO
2852,
BS
4825
/
ASME
BPE
or
DIN
32676.
0.1
0.3
0.5
1
3
5
10
0.01
0.02
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
m
3
/h
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
2000
3000
l/min
0.3
0.5
1
3
5
10
30
m/s
fps
US gpm
0.05
0.1
0.2
0.5
1
2
5
10
20
50
100
200
500
1000
DN 65
DN 50 (DN65)*
DN 40 (DN50)*
DN 32 (DN40)*
DN 25 (DN32)*
DN 20 (DN25)*
DN 15 (DN15 ou DN20)*
500
1000
2000
2000
5000
10000
5000
20000
5000
10000
20000
30000
50000
100000
DN 400
DN 350
DN 300
DN 250
DN 200
DN 150
DN 125
DN 100
DN 80
DN 6
DN 8
Example
DN400 DN350 DN300
DN250
DN200
DN150
DN125
DN100
DN80
(DN100)*
DN65
(DN80)*
DN50
(DN65)*
DN40
(DN50)*
DN32
(DN40)*
DN25
(DN32)*
DN20
(DN25)*
DN15
(DN15
or
DN20)*
DN8
DN6
m/s
fps
Fluid
velocity
flow rate
English
Type 8041