27

Adjustmentandcommissioning

+ -

18-36 VDC

250 VAC

L

N

300 mA

3 A

8041

C

NO

NC

4...20 V+ V- PE Pls+Pls-

*

1 2 3 4 5 6

250 VAC, 3 A max.

Power supply

Protection circuit

Relay protection cap

Solenoid valve

(or alarm)

* If direct earthing is not possible, connect a 100 nF / 50 V condensator
between the negative terminal of the voltage supply and the earth.

Fig. 25: Connection of the relay output for a normally closed

operating

9.

ADjusTmenT AnD
commissioninG

9.1.

safety instructions

danger

risk of injury due to electrical voltage.
• Observe all applicable accident protection and safety regula-

tions for electrical equipment.

Warning

risk of injury due to non-conforming operating.
Non-conforming operating could lead to injuries and damage the
device and its surroundings.
• The operators in charge of operating must have read and under-

stood the contents of these operating instructions.

• In particular, observe the safety recommendations and intended

use.

• The device/installation must only be operated by suitably trained

staff.

English

Type 8041