beautypg.com

General data – Burkert Type 8041 User Manual

Page 13

background image

11

Technicaldata

Table 4 : Dimension H in mm of the flowmeter 8041 with a clamp

connection and inserted into an S020 fitting

H

T-fitting

Welding socket

DN32

181

181

DN40

186

186

DN50

191

191

DN65

199

199

DN80

205

205

DN100

211

211

6.4.

General data

Pipe diameter

DN06 to DN400

Type of fitting

S020

Fluid conductivity

> 20 µS/cm

1)

Determined in the following reference conditions: fluid = water, water

and ambiant temperatures = 20 °C, upstream and downstream distances
respected, appropriate pipe dimensions

Fluid temperature

• with holder of the flow

sensor in stainless steel

• with holder of the flow

sensor in PVDF

The fluid temperature may be
restricted by the fluid pressure and
the material of the S020 fitting used
(see

Fig. 6 and Fig. 7).

• -15...+150 °C

• 0...+80 °C

Fluid pressure


• with holder of the flow

sensor in stainless steel

• with holder of the flow

sensor in PVDF

The fluid pressure may be restricted
by the fluid temperature, the material
of the S020 fitting used and the DN
of the S020 fitting used (see Fig. 6

and

Fig. 7).

• PN10 with a fitting in plastic,

PN16 with a fitting in metal

• PN10

Flow rate measurement

• Measuring range
• Linearity
• Repeatability
• Accuracy with standard

K factor

• Accuracy with Teach-in

• 0,2 to 10 m/s

1)

• ±0,5%

1)

of the full scale

• ±0,25%

1)

of the measured value

• ±3,5%

1)

of the measured value

• ±0,5%

1)

of the measured value

English

Type 8041