K factors (in pulse/l) of the fusion spigots and, Welding sockets with radius for measuring, Devices with a g2'' nut – Burkert Type S020 User Manual
Page 26

26
Technicaldata
Type S020
6.4.7. K factors (in pulse/l) of the fusion spigots and welding sockets with radius for
measuring devices with a g2'' nut
When	the	dimensions	of	the	pipe	are	slightly	different	from	dimensions	d	and	s	given	in	the	table,	recalculate	the	K	factor	using	one	of	
the	formulae	in	chap.	6.4.2.
If	the	measuring	device	does	not	automatically	convert	the	K	factor,	use	the	following	conversion	formulae	before	setting	the	para-
meters	of	the	device:
•	 K	factor	in	pulse/US	gallon	=	K	factor	in	pulse/litre	x	3.785
•	 K	factor	in	pulse/UK	gallon	=	K	factor	in	pulse/litre	x	4.546
Table 20: K factors, external diameters and theoretical cross sections of the welding sockets with radius, for measuring devices with a G2''
nut, and of the fusion spigots in plastic, used with a 8020, 8024, 8025 or 8026
measuring device inserted
8020, 8024, 8025, 8026
external diameters and theoretical cross-sections
material of the pipe
stainless
steel
pe / pp
pVdf
d
steel
[mm]
s
steel
[mm]
d
pe/pp
[mm]
s
pe/pp
[mm]
d
pVdf
[mm]
s
pVdf
[mm]
dn
50
13,0 (C)
-
-
60,3
2,0
-
-
-
-
65
7,86 (C)
8,32 (C)
5,53 (C)
76,1
2,9
75
6,9
75
2,5
80
5,52 (C)
5,49 (C)
3,65 (C)
88,9
3,2
90
8,2
90
2,8
100
3,20 (C)
3,51 (C)
2,34 (C)
114,3
3,6
110
10
110
3,5
110
-
-
-
-
-
-
-
-
-
125
2,00 (C)
2,66 (L)
-
139,7
4
140
12,8
-
-
150
1,32 (C)
2,12 (L)
-
168,3
4,5
160
14,6
-
-
180
-
-
-
-
-
200
18,2
-
-
200
0,72 (C)
0,98 (L)
-
219,1
6,3
225
20,5
-
-
250
0,50 (L)
0,63 (L)
-
273
7,7
280
25,5
-
-
300
0,35 (L)
0,42 (L)
-
323,9
9,5
315
28,7
-
-
350
0,26 (L)
0,30 (L)
-
355,6
10,1
355
32,3
-
-
400
-
0,23 (L)
-
-
-
400
36,4
-
-