Technicaldata
Type S020
Table 11: Dimensions of the S020 fitting with welding end connections acc. to EN ISO 1127 / ISO 4200, SMS 3008, BS 4825/ASME BPE
or DIN 11850 range 2, for measuring devices with a clamp connection
dn [mm]
p [mm] A [mm] standard
d [mm] s [mm]
A
P
D
S
32
-
130
EN ISO 1127 / ISO 4200 42.4
2
40
-
130
EN ISO 1127 / ISO 4200 48.3
2
42.5
110
SMS 3008
38
1.2
43.7
120.6
BS 4825 / ASME BPE
38.1
1.65
-
120
DIN 11850 range 2
41
1.5
50
-
180
EN ISO 1127 / ISO 4200 60.3
2
49.3
164
SMS 3008
51
1.2
50.6
146
BS 4825 / ASME BPE
50.8
1.65
-
160
DIN 11850 range 2
53
1.5
65
-
220
EN ISO 1127 / ISO 4200 76.1
2
54.4
210
SMS 3008
63.5
1.5
55.4
158.8
BS 4825 / ASME BPE
63.5
1.65
-
210
DIN 11850 range 2
70
2
80
-
260
EN ISO 1127 / ISO 4200 88.9
2.3
60.7
220
SMS 3008
76.1
1.6
62
171.5
BS 4825 / ASME BPE
76.2
1.65
-
260
DIN 11850 range 2
85
2
100
73.8
77.1
209.6
BS 4825 / ASME BPE
101.6
2.11
310
DIN 11850 range 2
104
2