K factors (in pulse/litre) for t fittings and wel, Ding sockets used with a 8041 or a 8045 with, Clamp connection – Burkert Type S020 User Manual
Page 23: A 8020, 8024, 8025 or 8026
23
Technicaldata
Type S020
6.4.4. K factors (in pulse/litre) for T
fittings and welding sockets used
with a 8041 or a 8045 with clamp
connection
Table 17: K factors of the T fittings for measuring devices with clamp
connection
Type of connection
and standard
DN40
DN50
DN65
DN80
DN100
acc. to SMS 3008 5.23
10.4
15.9
24.7
-
acc. to BS 4825 /
ASME BPE
5.33
10.4
16.7
25.7
50.3
acc. to DIN 11850
range 2
-
-
-
-
52.7
acc. to ISO 4200
-
-
-
-
-
6.4.5. K factors (in pulse/litre) for T fittings
used with a 8020, 8024, 8025 or
8026
If the measuring device does not automatically convert the K
factor, use the following conversion formulae before setting
the parameters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546
Two versions of the S020 in DN15 and DN20 exist, having
different K factors.
Only version 2, identified by the "v2" marking, is available
from March 2012. The "v2" marking can be found:
• on the bottom of the DN15 fitting in plastic:
V2
• on the side of the DN15 or DN20 fitting in metal:
V2
Do not use a fitting S020 in sizes DN6, DN8, DN15, DN15
Version 2 (V2) or DN20 Version 2 (V2) with a paddle-wheel
flowmeter types 8020, 8024, 8025, 8026.
English