K factors (in pulse/litre) for t fittings and wel, Ding sockets used with a 8041 or a 8045 with, Clamp connection – Burkert Type S020 User Manual
Page 23: A 8020, 8024, 8025 or 8026

23
Technicaldata
Type S020
6.4.4. K factors (in pulse/litre) for T
fittings and welding sockets used 
with a 8041 or a 8045 with clamp 
connection
Table 17: K factors of the T fittings for measuring devices with clamp
connection
Type of connection
and standard
DN40
DN50
DN65
DN80
DN100
acc. to SMS 3008 5.23
10.4
15.9
24.7
-
acc.	to	BS	4825	/	
ASME	BPE
5.33
10.4
16.7
25.7
50.3
acc. to DIN 11850
range 2
-
-
-
-
52.7
acc. to ISO 4200
-
-
-
-
-
6.4.5. K factors (in pulse/litre) for T fittings
used with a 8020, 8024, 8025 or 
8026
If	the	measuring	device	does	not	automatically	convert	the	K	
factor,	use	the	following	conversion	formulae	before	setting	
the	parameters	of	the	device:
•	 K	factor	in	pulse/US	gallon	=	K	factor	in	pulse/litre	x	3.785
•	 K	factor	in	pulse/UK	gallon	=	K	factor	in	pulse/litre	x	4.546
Two	versions	of	the	S020	in	DN15	and	DN20	exist,	having	
different	K	factors.
Only	version	2,	identified	by	the	"v2"	marking,	is	available	
from	March	2012.	The	"v2"	marking	can	be	found:
•	 on	the	bottom	of	the	DN15	fitting	in	plastic:
V2
• on the side of the DN15 or DN20 fitting in metal:
V2
Do	not	use	a	fitting	S020	in	sizes	DN6,	DN8,	DN15,	DN15	
Version	2	(V2)	or	DN20	Version	2	(V2)	with	a	paddle-wheel	
flowmeter	types	8020,	8024,	8025,	8026.
English